Service manual

EPSON Stylus Photo R340/350 Revision A
Disassembly and Assembly Disassembly 54
2.3.9 Removing the Main Board Assy.
Illustration (1)
Figure 2-24. Removing the Main Board Assy. (1)
Parts/Components must be removed to remove the Main Board Assy.
Paper Support Assy., Left Housing, Right Housing,
Panel Board Assy. (Panel Board and LCD Module), Upper Housing
Disassembly Procedure
1. Unlock the carriage lock with tweezers and move the Carriage Unit to the
center.
2. Remove the two pieces of two-sided tape that secure the Panel FFC and LCD
FFC and disconnect the FFCs from the Main Board Assy.
3. Disconnect the other connector cables from the Main Board Assy.
4. Remove the two screws ( ) that secure the M/B Grounding Plate and
remove it.
Two-sided Tapes
Connectors
LCD FFC
Panel FFC
Carriage Lock
Carriage Unit
Other Connector Cables
M/B
Grounding
Plate
C.B.S 3x6
(4-5kgf.cm)
C.B.S 3x6
(6-8kgf.cm)
Positioning
Holes
1