Service manual
EPSON Stylus Photo R340/350 Revision A
Troubleshooting Troubleshooting 16
Table 1-6. Troubleshooting of Fatal Errors based on Observed Symptom
Occurrence
Timing
CR Position
Symptoms Failed Part Check Point Remedies
• Occurrence
Timing:
At power-on
• CR Position:
---
The CR Motor does not start to operate
at all by turning the power On.
CR Motor 1. Check if the CR Motor cable is correctly connected to
CN11 on the Main Board.
1. Correctly connect the CR Motor cable to
CN11 on the Main Board.
2. Check the CR Motor if it works properly. 2. Replace the CR Motor with a new one.
The Carriage Unit hits against the
Change Lever which has inclined toward
the front of the printer at power-on.
PF Motor 1. Check if the PF Motor cable is correctly connected to
CN10 on the Main Board.
1. Correctly connect the PF Motor cable to
CN10 on the Main Board.
2. Check the PF Motor resistance with a tester if it is 3.0 Ω.
See Table 1-1 on page 8.
2. Replace the PF Motor with a new one.
Ink System 1. Check if the Compression Spring 2.36 in the Change
Lever has not come off.
1. Replace the Ink System with a new one.
CN11
CN10
Change Lever
Compression
Spring 2.36