Service manual

EPSON Stylus Photo R340/350 Revision A
Maintenance Overview 115
<Lubrication Point>
The Driven Pulley Assy.
<Lubrication Type>
G-26
<Lubrication Amount>
1mm x 4 points
<Remarks>
Use a syringe. (both metallic and
plastic needles are OK.)
<Lubrication Point>
Specified points on the Left Scale
Holder in the figure on the left
<Lubrication Type>
G-63
<Lubrication Amount>
8 points (Adequate dose)
<Remarks>
Use a brush to apply it
Driven Pulley Assy.
Lubrication Point
Lubrication Point
(Upper Surface)
Lubrication Point
(Upper Surface)
Lubrication Point
(Inside Surface of Hole)
Lubrication Point
(Both Sides Close to Upper
Surface)
Left Scale Holder
<Lubrication Point>
Specified points on the Right
Scale Holder in the figure on the
left
<Lubrication Type>
G-63
<Lubrication Amount>
8 points (Adequate dose)
<Remarks>
Use a brush to apply it
<Lubrication Point>
Inside periphery surface of the
Right CR Cam
<Lubrication Type>
G-63
<Lubrication Amount>
4 points (Adequate dose)
<Remarks>
Use a brush to apply it
Do not apply it outside the
boundary in the figure
Right Scale Holder
Lubrication Point
(Inside Surface of Hole)
Lubrication Point
(Upper Surface)
Lubrication Point
(Both Sides Close to Upper
Surface)
Right CR Cam
Boundary
Lubrication Point