Service manual
EPSON Stylus Photo R260/R265/R270, R360/R380/R390 Revision B
Disassembly/Assembly Disassembly of the Printer Mechanism 96
4. Follow the steps below to remove the CDR Guide Lever Spring.
1) Pull the end A toward you.
2) Pull the end B out of the notch.
3) Pull the end A out of the shaft, and remove the CDR Guide Lever Spring.
Figure 4-110. Removing the CDR Guide Lever Spring (2)
5. Remove the four screws that secure the Stacker Assy.
• Screw : C.B.P. M3x8 (tightening torque: 5-7 kgf.cm)
(The numbers shown in the figure indicate the order of tightening the screws.)
6. Holding the Left/Right Stacker Guides, remove the Stacker Assy from the
Lower Housing.
Figure 4-111. Removing the Stacker Assy
7. While disengaging the hook, remove the left gear from the CDR Shaft and
remove the Left Stacker Guide. Also remove the Right Stacker Guide in the
same way.
8. Remove the CDR Shaft from the Stacker.
Figure 4-112. Removing the CDR Shaft
1
A
CDR Shaft
2
3
B
A
1
2
3
4
Left Stacker Guide
Stacker Assy
Right Stacker Guide
Lubrication is required. See the page given below for the
lubrication information.
"6.1.3 Lubrication (p.131)"
Install the CDR Shaft so that one of its gear holes further to the
shaft end goes to the left (the spring attached side).
When attaching the CDR Shaft, make sure to match the phases
of the left and right gears as shown below.
• Insert the gear tooth with a small protrusion on its root into
the groove between the 3rd and 4th teeth of the Stacker
Guide Left/Right.
Figure 4-113. Reinstalling the CDR Shaft
Right Stacker Guide
Left Stacker Guide
[Left side]
[Right side]
CDR
Shaft
: Hook
3
4
CDR Shaft
Tooth with protrusion
Right Stacker Guide