Service manual

EPSON Stylus Photo R260/R265/R270, R360/R380/R390 Revision B
Disassembly/Assembly Disassembly of the Printer Mechanism 111
4.5.15 CDR Guide Detection Assy
Parts/Components need to be removed in advance
All exterior parts/components / All control boards / Middle Housing / Printer
Mechanism / CR Scale / APG Unit / Printhead / Ink System / ASF Unit / Upper Paper
Guide / Front Paper Guide Assy / CR Motor / EJ Frame Assy / PF Encoder / PF Scale /
CR Unit
Removal procedure
1. Disengage the two hooks and remove the CDR Guide Sensor from the frame.
Figure 4-164. Removing the CDR Guide Sensor
2. Disengage the hook of the CDR Tray Sensor.
3. Turn the CDR Tray Sensor 90 degrees in the direction of the arrow to
disengage its another hook, and pull it out from the hole to remove it together
with the CDR Guide Sensor.
Figure 4-165. Removing the CDR Tray Sensor (CDR Guide Detection Assy)
C H E C K
P O I N T
The CDR Guide Detection Assy consists of the CDR Guide Sensor,
CDR Tray Sensor and the connector cables.
Figure 4-163. CDR Guide Detection Assy
CDR Guide Sensor
CDR Tray Sensor
Removal Direction
CDR Guide Sensor
Hook
C A U T I O N
Always follow the steps below to remove the CDR Tray Sensor, or
one of its hooks can be broken.
90-degrees Turn
Hook
CDR Tray Sensor