Service manual

EPSON Stylus Photo R260/R265/R270, R360/R380/R390 Revision B
Disassembly/Assembly Disassembly of the Printer Mechanism 101
3. Disengage the connector cables of the PE Sensor and the APG Sensor from
the two hooks (A).
4. Remove the two screws and remove the Cable Holder Frame from the two
hooks (B).
Screw : C.B.S. M3x6 (tightening torque: 7-9 kgf.cm)
(The numbers shown in the figure indicate the order of tightening the screws.)
Figure 4-128. Removing the Cable Holder Frame
5. Remove the left and right screws, and remove the Front Frame.
Screw : C.B.S. M3x6 (tightening torque: 7-9 kgf.cm)
(The numbers shown in the figure indicate the order of tightening the screws.)
Figure 4-129. Removing the Front Frame
6. Remove the EJ Frame Assy.
Figure 4-130. Removing the EJ Frame Assy
PE Sensor Cable
APG Sensor Cable
Cable Holder Frame
1
2
: Hook A
: Hook B
Removal Direction
1
2
Front Frame
Lubrication is required. See the page given below for the
lubrication information.
"6.1.3 Lubrication (p.131)"
When installing the EJ Frame Assy, insert its two lower
bushings over the EJ Roller Shaft.
Figure 4-131. Reinstalling the EJ Frame Assy
When installing the EJ Frame, make sure that the Left/Right EJ
Frame Springs are attached as shown in the figure below.
Carefully handle the EJ Frame as the springs come off easily.
Figure 4-132. Reinstalling the Front Frame (1)
EJ Frame Assy
Removal Direction
Bushing
Bushing
EJ Roller Shaft
EJ Frame Assy
Left EJ Frame Spring
Right EJ Frame Spring
Shorter
Longer