Specifications
CALCulate Subsystem ZVx
1043.0009.50 3.40 E-15
3.6.3.8 CALCulate:TRANsform Subsystem
The CALCulate:TRANsform subsystem defines the transformation of data sets into other
representations.
COMMAND PARAMETER UNIT COMMENT
CALCulate<1..4>
:TRANsform
:COMPlex
ZREFerence
:TIME
:STATe
:METHod
[:TYPE]
:LPASs
:DCSParam
:STIMulus
:STARt
:STOP
:SPAN
:CENTer
:WINDow
:DCHebyshev
:XAXis
S | SINV | Y | Z | YREL | ZREL
<numeric_value>
<Boolean>
FFT | CHIRp
BPASs | LPASs
KFSTop | KDFRequency | MINStep
<numeric_value>
IMPulse | STEP
<numeric_value>
<numeric_value>
<numeric_value>
<numeric_value>
RECT | HAMMing | HANNing |
BOHMan | DCHebyshev
<numeric_value>
TIME | DISTance | HDIStance
OHM
s | m
s | m
s | m
s | m
dB
CALCulate[1...4]:TRANsform:COMPlex
This command defines the transformation of data sets.
Syntax: CALCulate[1...4]:TRANsform:COMPlexS | SINV | Y | Z | YREL | ZREL
Example: "CALC:TRAN:COMP SINV"
Features: *RST value: –
SCPI: device-specific
CALCulate[1...4]:TRANsform:COMPlex:ZREFerence
This command defines the reference impedance for the normalized measured quantities.
Syntax:
CALCulate[1...4]:TRANsform:COMPlex:ZREFerence <numeric_value>
Example:
"CALC:TRAN:COMP:ZREF 30 Ohm"
Features:
*RST value:
SCPI:
50 Ω
device-specific
CALCulate[1...4]:TRANsform:TIME:STATe
This command switches ON or OFF the time domain transformation.)
Syntax:
CALCulate[1...4]:TRANsform:TIME:STATe ON | OFF
Example:
"CALC:TRAN:TIME:STATe ON"
Features:
*RST-Wert:
SCPI:
OFF
conforming