ZVx Structure and Syntax of the Device Messages
1043.0009.50 3.9 E-15
Device-specific commands
Hierarchy: Device-specific commands are of hierarchical structure (see Fig. 3-1).
The different levels are represented by combined headers. Headers of
the highest level (root level) have only one key word. This key word
denotes a complete command system.
Example: SENSe This key word denotes the command system
SENSe.
For commands of lower levels, the complete path has to be specified,
starting on the left with the highest level, the individual key words being
separated by a colon ":".
Example: SENSe:FREQuency:SPAN 100E6
This command lies in the fourth level of the SENSe system. It
determines which parameter remains unchanged when the span is
changed. If LINK is set to STARt, the values of CENTer and STOP are
adjusted when the span is changed.
SENSe
BANDwidth
FREQuency
STOP
CENTer
SPANSTARt
Fig. 3-1Tree structure of the SCPI command systems: The SENSe system
Some key words occur in several levels within one command system. Their
effect depends on the structure of the command, that is to say, at which
position in the header of a command they are inserted.
Example: SOURce:FM:POLarity NORMal
This command contains key word POLarity in the third
command level. It defines the polarity between modulator and
modulation signal.
SOURce:FM:EXTernal:POLarity NORMal
This command contains key word POLarity in the fourth
command level. It defines the polarity between modulation
voltage and the resulting direction of the modulation only for the
external signal source indicated.