Specifications

ZVx Test Sequence (R&S ZVC, R&S ZVCE)
1043.0009.50 5.43 E-7
Measurement Set test frequencies according to test report.
Measure at twice and three times the test frequency and calculate the difference
from the measured value at the test frequency, report the worse of the two values.
Test frequency range Harmonics suppression at
-10
dBm
Pmax
40 kHz to 8 GHz -35
dBc -25 dBc
With option R&S ZVR-B10:
0
dBm Pmax
20 kHz to 40 kHz -30 dBc -20 dBc
40 kHz to 20 MHz -30 dBc -22 dBc
20 MHz to 70 MHz -35 dBc -22 dBc
70 MHz to 2 GHz -35 dBc -25 dBc
2 GHz to 8 GHz -32 dBc -20 dBc
If a network analyzer ZVx is used the 2
nd
harmonic wave can be measured up to 4000
MHz fundamental only. Due to the strong reduction of the Output Stage amplification
in the range above 8 GHz, a measurement at higher frequencies is not necessary.
5.5.1.3 Spurious Suppression
Test equipment: Test cable, option R&S ZVR-B4, attenuator RSG or RSM
Test setup: Connect RSG (RSM) via test cable between PORT1 and PORT2.
Settings of the attenuator: 30 dB
Settings at the network analyzer:
PRESET
MODE FREQUENCY CONVERSION : ARBITRARY
Meas. frequency = INT SRC
REC = spurious wave
SOURCE POWER 0 dBm and –10 dBm
-3 dBm and –10 dBm at f > 6GHz
MEAS INPUT b2, DRIVE PORT 1
Reference
measurement:
Record measured values at the test frequencies.