Specifications

Test Sequence (R&S ZVR, R&S ZVRE, R&S ZVRL) ZVx
1043.0009.50 5.14 E-7
R&S ZVRL
Measurement
PORT2:
Measurement
PORT1
As with R&S ZVR and R&S ZVRE
With further network analyzer ZVx as with R&S ZVR and R&S ZVRE.
Measurement:
Set test frequencies according to test report.
Record return loss values.
Test frequency: Return loss
PORT1 50 : PORT1 75 : PORT2:
40 kHz to 100 kHz > 10 dB > 6 dB > 18 dB
100 kHz to 100 MHz > 16 dB >12 dB > 18 dB
100 MHz to 3000 MHz > 18 dB >18 dB > 18 dB
3000 MHz to 4000 MHz > 16 dB >15 dB > 18 dB
5.2.3.2 Directivity
Test equipment MATCH from calibration kit
Test setup:
Connect MATCH at PORT1 or PORT2.
Settings at the network analyzer:
PRESET
SWEEP LOG SWEEP
MEAS S11
S22 (R&S ZVR, R&S ZVRE only)
MARKER test frequency
Measurement:
50 9 75 9
Passive test set:
Test frequency: Directivity: Directivity:
9 kHz to 40 kHz 25 dB 25 dB
40 kHz to 3 GHz 33 dB 33 dB
3 GHz to 4 GHz 29 dB 20 dB
Active test set:
Test frequency: Directivity: Directivity:
300 kHz to 1 MHz 5 dB 5 dB
1 MHz to 5 MHz 15 dB 15 dB
1 MHz to 3 GHz 33 dB 33 dB
3 GHz to 4 GHz 29 dB 20 dB