Specifications

Test Sequence (R&S ZVR, R&S ZVRE, R&S ZVRL) ZVx
1043.0009.50 5.10 E-7
Measurement:
Set test frequencies and levels according to test report, report measurement
results and subtract the reference values.
D
eviation from
reference value (-10 dBm): Permissible deviation:
20 kHz to 200 kHz +10 dB to +3 dB <1 dB
+ 3 dB .to -15 dB <0.2 dB
200 kHz +10 dB to +3 dB <1 dB
+ 3 dB to -5 dB <0.2 dB
- 5 dB to -60 dB <0.05 dB
5.2.2.3 Noise Level
Test equipment:
Test cable ZV-Z11 (ZV-Z12 for 75 test set) MATCH from calibration kit ZV-Z21
(ZCAN for 75 test set).
Calibration: Connect PORT1 to PORT2 via test cable.
MEAS : INPUT b1, INPUT b2
TRACE : DATA TO MEMORY : SHOW MATH
Test setup: MATCH at PORT1 or PORT2.
Settings at the network analyzer:
PRESET
SOURCE POWER -25 dBm
MEAS INPUT b1, INPUT b2
AVG SWEEP AVG 10
MARKER MARKER CONT
MARKER Marker frequency = test frequency
Measurement:
Set test frequencies according to test report.
Read marker value on the network analyzer taking the SOURCE POWER into
account (–10 dB for 50 test set, –4 dB for 75 test set).
Permissible noise values:
Test set 50 , passive Test set 75 , passive
9 kHz to 200 kHz -65 dBm -50 dBm
200 kHz to 20 MHz -85 dBm -70 dBm
20 MHz to 3 GHz -95 dBm -80 dBm
3 GHz to 4 GHz -85 dBm -80 dBm
Test set 50 , active Test set 75 , active
300 kHz to 1 MHz -82 dBm -70 dBm
1 MHz to 20 MHz -85 dBm -80 dBm
20 MHz to 3 GHz -95 dBm -75 dBm
3 GHz to 4 GHz -85 dBm -75 dBm