Specifications
ZVx Test Sequence (R&S ZVR, R&S ZVRE, R&S ZVRL)
1043.0009.50 5.7 E-7
Measurement:
Set test frequencies and levels according to test report, read the level on the
power meter.
Permissible deviations referred to the value at -10 dBm (+3 dBm at PORT 1 with Opt.
R&S ZVR-B10):
f = 40 kHz to 4 GHz
+
10 to –5 dB < 0.4 dB
–5 dB to –15 dB < 0.6 dB
5.2.1.7.1 Matching to Output a1
(Only with option R&S ZVR-B25, External Measurements)
Test equipment: Signal generator SME 06, Spectrum Analyzer FSB, VSWR–bridge ZRC
Test setup:
ZVRx
Port 1 Port 2
SME 06 FSB
ZRC
Settings at the network analyzer:
SWEEP SINGLE POINT
CENTER Test frequency + f
SWEEP TIME 500 s
SOURCE POWER –10 dB
MODE EXTERNAL
Reference
measurement:
Use FSB to record measured values with open circuit and short circuit at the test
port of the SWR bridge and take the average.
Measurement:
Test frequency (FSB): f: Return loss:
400 kHz
1)
to 4000 MHz – 100 kHz > 8 dB