Specifications
Test Sequence (R&S ZVR, R&S ZVRE, R&S ZVRL) ZVx
1043.0009.50 5.4 E-7
Measurement: Set test frequencies according to test report.
Mixer range up to 750 MHz: LO=RF+fo (fo = test frequency)
For fo < 50 MHz RF = 63.125 MHz
fo = 50 MHz to < 150 MHz RF = 252.5 MHz
fo = 150 MHz to 750 MHz RF = 1010 MHz
Perform measurements for f = 2
*
RF - LO and f = 3
*
RF - 2
*
LO.
Permissible spurious suppression < – 40
dBc
Doubled range > 2000 MHz to 4000 MHz:
Perform measurements for f = fo/2 and f = 3fo/2
Permissible spurious suppression < -40 dBc
5.2.1.4 Phase Noise
Test equipment: Modulation Meter FMB with Option FMA-B8, matching pad RAM for 75 test set
Test setup: Connect modulation meter (operating mode DEMOD PM PHASENOISE 10 kHz)
to PORT1 of the network analyzer (RAM to FMB for 75 ).
Settings at the network analyzer:
PRESET
SWEEP SINGLE POINT
CENTER Test frequency
SOURCE POWER Maximum level
SWEEP TIME 200 s
MEAS INPUT a1
Measurement Set test frequencies according to test report, read the phase noise value on the
modulation meter.
Permissible phase noise values:
9 kHz to 10 MHz < -110 dBc
10 MHz to 150 MHz < -100 dBc
150 MHz to 1 GHz < -90 dBc
1 GHz to 4 GHz < -90 dBc + 20
*
log(f / GHz)
(< -78 dBc at 4 GHz)