Technical data
1-8
Specifications and Regulatory Information
Specifications and Characteristics
Electrical-to-Optical Device Measurement Specifications
Relative frequency response can be used to calculate the error in measuring the 3 dB bandwidth of an E/O
device.
Relative Frequency Response Performance Data
Figure 1-5. E/O Characteristic Relative Frequency Response Error
Electrical-to-Optical Measurement Performance Data
Description Frequency Range
Specification
a
a. Applies to a device with ρ = <0.25 and measurement settings of IF bandwidth = 30 Hz and smoothing = 0.5%.
System Relative Frequency Response Accuracy 0.05 to 0.5 GHz ±1.15 dB
0.05 to 11 GHz ±0.85 dB
11 to 20.05 GHz ±0.90 dB