Test Mode
Test Mode is reached from normal print operation. It is used to access
a number of internal functions. Normal print operation is inhibited.
Set the rotary switch to position ‘9‘. When the SYSTEM indicator
starts to flash, you can select one of the following Test Mode
functions:
Do not forget to set the rotary switch to “0” again for normal print
operation.
Pos. Test Mode Function
0
Restart
- same as power off/power on.
1
Set Factory Defaults
- abandon the current configuration.
2
Print Character Translation Table
- see Appendix B.
3
ASCII Hex Dump Mode
- trap the outgoing data stream and print characters
and control commands as hexadecimal values.
4
System Hex Dump Mode
- trap the incoming data stream and print characters
and control codes as hexadecimal values.
5, 6 Reserved
7
Terminal Set-Up Mode
- run the Configuration Utility using a directly attached
3270 terminal, see Section 3.
8
Print Parameter List
- print the complete configuration, see Appendix A.
9
Exit Test Mode
- resume normal print operation.