MFJ-1289 Multicom User's Manual Page 23
3. Data Bits: 7
4. Parity: even
Press <Esc> to make a temporary change and go back to the terminal.
Turn your TNC off, then on again, and press the return key several times. At this
point, the TNC should sign-on.
NOTE: Older 1270s and 1274 TNCs might not work at 9600 baud. Check
for the signon at 4800 baud also. If the signon is OK at 4800, call MFJ for
the 9600 baud modification
To change the TNC settings to Multicom's default, set AWLEN to 8 and
PARITY to 0 by typing the following at the CMD: command prompt:
cmd: AWLEN 8 <Enter>
cmd: PARITY 0 <Enter>
After the above parameters are set properly, turn off your TNC. Press <F3>
for the setup screen and reset the terminal parameters so that Data Bits is set to
8 and parity is set to none. Press S to exit the setup screen. Turn the TNC back
on, press the <Enter> key several times, and the controller should sign-on.
To automatically set up your TNC, you can create a pre-configured file called
CONFIG.PRM to send to the controller on demand.
You must first create the CONFIG.PRM file. See the editor section on page
XX for information on how to create this file.