Operating instructions

4-19
MLC 104 Plus Series • SIS Programming and Control
PRELIMINARY
Command/response table for SIS commands (continued)
Command ASCII (Telnet)
(host to MLC)
URL Encoded (Web)
(host to MLC)
Response
(MLC to host)
Additional description
Show the absence of or types of connected
devices.
Prefixes for connected devices:
P1 = SCP #1, address 0
P2 = SCP #2, address 1
K1 = control module #1, address 0
K2 = control module #2, address 1
K3 = control module #3, address 2
K4 = control module #4, address 3
S = MediaLink device, typically
a slaved (auxiliary) MLS
switcher.
For :
00 = not present
01 = MLS 306
02 = MLS 506
03 = MLS 506MA 70 V
04 = MLS 506SA
05 = MLS 506MA 100 V
06 = MLS 100 A
07 = MLS 103 V
08 = MLS 103 SV
09 = MLS 102 VGA
10 = MLA-VC10
11 = MLS 304MA
12 = MLS 406
13 = MLS 406MA
14 = MLS 406SA
15 = MLS 304SA
16 = PVS 204SA
99 = non-MLS, non-
PVS switcher.
For ##:
00 = not present
01 = present (SCP)
or IRCM-VCR
02 = IRCM-DVD
03 = IRCM DVD+
04 = ACM-Level
05 = ACM-Tone
06 = RCM-SC
07 = RCM-SCLT
08 = IRCM-Tape
09 = CM-5BB
10 = CM-20BB
11 = IRCM-DV+
12 = CM-9BLB
13 = CM-3BLB
14 = CM-19AC
99 = unrecognized.
000 = not present 101 = IPI 101 AAP 104 = IPI 104 AAP
For ???:
Examples:
32I 32I
P101 P200 K111 K211 K307 K408 S09
]
This example includes one SCP (P101),
an IRCM-DVD+ (K111 and K211), an
RCM-SCLT (K307), an IRCM-Tape (K408),
and an MLS 102 VGA (S09).
IP setup commands (IP models only)
Set the unit name
24
E X1@
C N
}
W
X1@
CN
|
Ipn•
X1@ ]
Change the MLC’s name to one of your
choosing (
X1@
), such as “AuditoriumMLC”,
“Rm316-AVcenter”, or “exec-boardroom-
ctrl”. The name consists of up to 24
alphanumeric characters (and the minus
sign). The first character must be a letter,
the last character cannot be a minus sign
(hyphen). Either case (upper, lower) is OK.
Set unit name to factory default
24
E
•CN
}
W%20CN
|
Ipn•
X4( ] X4(
= the name the MLC was shipped with:
MLC-104-IP-PLUS-##-##-##, a combination
of the model name and the last 3 pairs
of hex numbers in the controller’s MAC
address (e.g., MLC-104-IP-PLUS-02-74-62).
Read the unit name
E
CN
}
WCN
| X1@ ]
or
X4( ] X1@
is the MLC’s current, user-defined unit
name.
X4(
is the MLC’s factory default name.
N