Command/response table for SIS commands (continued)
Command ASCII (Telnet)
(host to MLC)
URL Encoded (Web)
(host to MLC)
Response
(MLC to host)
Additional description
View the lockout mode status X X
X20(]
Show lockout (executive mode) status.
X20(
= 0 (off, unlocked) or 3 (front panels,
control modules, and remote control
locked/disabled).
Example:
X X
0
]
Executive mode is off.
Status commands
View lamp hours status 6S 6S
X20%]
or
X20%
*
X20%] X20%
represents the number of elapsed
hours of projector lamp use. The MLC
responds with two sets of lamp hours only
if two lamp hours have been set. If a lamp’s
status has not been set, it is shown as the
default (99999 hours) or “N/A”.
Set lamp hours status for 1 lamp
24
X20%
*6S
X20%
%2A 6S Lhr*
X20%
] X20%
represents the five-digit numeric v
alue for elapsed lamp use hours, and it is
used by script to determine the number
sent in response to the “view lamp hours”
command (6S).
Set lamp hours status for 2 lamps
24
X20%
*
X20%
*6S
X20%
%2A
X20%
%2A 6S Lhr*
X20%
*
X20%]
View connection status 7S 7S
X21^]
This command lets you know whether
the MLC’s scripts have determined if the
display is still connected to the MLC.
X21^
= 0 (disconnected), 1 (connected), or 2
(unknown).
Set display connection status
24
X21^
*7S
X21^
%2A 7S Pcs
X21^]
This command is used to reset the
projector/display connection status flag
(
X21^
) used by scripts.
0 = projector not connected.
1 = projector is connected.
2 = undetermined status.