Operating instructions
5-23
MLC 104 Plus Series • Special Applications
PRELIMINARY
4. In the Button Operations area, click the Digital Output tab.
5. Under Digital Output #1, click Off.
This command ensures that the relay is open (off) before it is pulsed.
6. Click the green arrow ( ) adjacent to the Press area or drag the command to
the Press area.
7. Under Digital Output #1, click Pulse.
8. Select a pulse time (duration) of 2.0 seconds.
9. Click the green arrow ( ) adjacent to the Press area or drag the Pulse command
to the Press area.