Service manual
LX-300+ Revision A
Product Description Interface Specifications 22
* In/Out shows the direction of signal flow from the printer’s point of view.
1.3.3 Serial Interface
Synchronization: Asynchronous
Signal level: EIA-232D
MARK (logical 1): -3V to -25V
SPACE (logical 0): +3V to +25V
Word length: Start bit: 1 bit
Data bit: 8 bit
Parity bit: Odd, Even, Non, Ignore
Stop bit: 1 bit or more
Baud rate: 300, 600, 1200, 2400, 4800, 9600 or 19200 bps
Handshaking: DTR signal and XON/XOFF
DTR=MAEK, XOFF:indicates that the printer cannot receive data.
DTR=MARK, XON: indicates that the printer is ready to receive data.
NOTE: The DTR signal is MARK and XOFF code (DC3, 13H) is
transmitted when the rest of the input buffer becomes 256
bytes. The DTR signal is SPACE and XON code (DC1, 11H) is
transmitted when the rest of the input buffer is regained 256
byte.
Error handling: Parity error is only detected. Overrun error and
framing error are ignored.
Connector: 25 pin subminiature D-shell connector (female)
* In/Out shows the direction of signal flow from the printer’s point of view.
35 +5V -- Out
This line is pulled up tp +5V
through 1.0 k
Ω
resister.
17 Chassis -- -- Chassis GND.
16, 33,
19-30
GND -- --
Signal GND.
15, 34 NC -- -- Not connected.
Table 1-15. Connector Pin Assignment and Signals
Pin
No.
Signal Name
Return
GND
Pin
In/Out Functional Description
Table 1-16. Connector Pin Assignment and Signals
Pin
No.
Signal Name In/Out Functional Description
2 TXD Out Transmit data.
20 DTR Out
Indicates that the printer is ready to receive data
or not.
11 REV Out Connected directly to the DTR signal.
4 RTS Out
Request to send. Always SPACE level when the
printer is powered on. Pulled up to +12V via
4.7K
Ω
resistor.
3 RXD In Receive data.
7 Signal GND -- Signal GND
1 Chassis GND -- Chassis GND
other NC -- Not used. Not connected.