Specifications

Rev. A Adjustments and Settings 2-11
TM-J7000/TM-J7100 Developers Guide
Confidential
Data length, handshake, or parity
Press the FEED button the number of times required to select the desired Data length,
handshake, or parity setting used for transmission conditions.
Transmission-related conditions (Advanced Interface Setup)
Press the FEED button the number of times required to select the desired Receive buffer size,
receive error sequence, or busy condition setting used for transmission-related conditions.
Automatic line feed (CR command function)
Press FEED button Setting selected
Data Length Handshake Parity
0 times: No change
1 time: 8 bits DTR/DSR control None
2 times: Even
3 times: Odd
4 times: XON/XOFF control None
5 times: Even
6 times: Odd
7 times: 7 bits DTR/DSR control None
8 times: Even
9 times: Odd
10 times: XON/XOFF control None
11 times: Even
12 times: Odd
13 or more times: No change
Press FEED button Setting selected
Receive error sequence BUSY condition
0 times: No change
1 time: Change to '?' Offline or receive buffer full
2 times: Receive buffer full
3 times: Ignore Offline or receive buffer full
4 times: Receive buffer full
5 or more times: No change