Specifications
2-10 Adjustments and Settings Rev. A
Confidential
Selecting individual settings
❏ Autocutter
Press the FEED button the number of times required to select the desired Autocutter setting.
❏ Basic serial interface setting
To select transmission conditions, first choose “Serial interface settings”; then select “Data
length, handshake, or parity.”
Press the FEED button the number of times required to select the desired “Serial interface
settings” used for transmission conditions.
bps: Indicates the number of transmitted bits per second (bps).
Press FEED button Setting to select
0 times: No change
1 time: Autocutter enabled
(Note: “Installed” is printed in the setting guidance)
2 times: Autocutter disabled
(Note: “Not installed” is printed in the setting guidance)
3 or more times: No change
Press FEED button Setting selected
0 times: No change
1 time: 115200 bps
2 times: 57600 bps
3 times: 38400 bps
4 times: 19200 bps
5 times: 9600 bps
6 times: 4800 bps
7 times: 2400 bps
8 or more times: No change