Scara Robot Manipulator Manual
Maintenance 3. Covers 
3.5 Connector Sub Plate 
■ 
Do not remove the connector sub plate forcibly.  Removing the connector sub 
plate forcibly may result in damage to the cables, disconnection, and/or contact 
failure. Damaged cables, disconnection, or contact failure is extremely 
hazardous and may result in electric shock and/or improper function of the robot 
system. 
CAUTION 
■ 
When installing the connector sub plate, be careful not to allow the cables to 
interfere with the plate mounting and do not bend these cables forcibly to push 
them into the cover. 
Unnecessary strain on cables may result in damage to the cables, disconnection, 
and/or contact failure. Damaged cables, disconnection, or contact failure is 
extremely hazardous and may result in electric shock and/or improper function of 
the robot system. 
When routing the cables, observe the cable locations after removing the 
connector sub plate.    Be sure to place the cables back to their original locations.
Unscrew the connector sub plate mounting bolts and remove the plate. 
  G3-**1* Table Top Mounting    G3-**1*W Multiple Mounting 
Truss: 
4-M4×8 
Connector sub plate
Truss: 4-M4×8 
Connector sub plate
3.6 User Plate 
Unscrew the user plate mounting bolts and remove the plate. 
G3-**1S* Standard-model  G3-**1C* Cleanroom-model 
User plate
Truss: 4-M4
×
8
3-M4
×
12
Gasket 
Truss: 4-M4×8
3-M4×12
User plate
A gasket is installed to G3-**1C* (Cleanroom-model). 
G3 Rev.1  79 