Scara Robot Manipulator Manual
Maintenance 3. Covers 
3.4 Connector Plate 
■ 
Do not remove the connector plate forcibly. Removing the connector plate 
forcibly may result in damage to the cables, disconnection, and/or contact failure.   
Damaged cables, disconnection, or contact failure is extremely hazardous and 
may result in electric shock and/or improper function of the robot system. 
CAUTION 
■ 
When installing the connector plate, be careful not to allow the cables to interfere 
with the plate mounting and do not bend these cables forcibly to push them into 
the cover. 
Unnecessary strain on cables may result in damage to the cables, disconnection, 
and/or contact failure. Damaged cables, disconnection, or contact failure is 
extremely hazardous and may result in electric shock and/or improper function of 
the robot system. 
When routing the cables, observe the cable locations after removing the 
connector plate.    Be sure to place the cables back to their original locations. 
Unscrew the connector plate mounting bolts and remove the plate. 
  G3-**1* Table Top Mounting  G3-**1*W Multiple Mounting 
Truss: 
4-M4×8 
Connector plate 
Truss: 
4-M4×8
Connector plate
78  G3 Rev.1 