Scara Robot Manipulator Manual
Setup & Operation 4. Setting of End Effectors 
G3 Rev.1  41 
<Example> A “1 kg” camera is attached to the end of the G3 series arm (180 mm
away from the rotation center of Joint #2) with a load weight of “1
kg”. 
 M = 1 
L
2
 = 130 
L
M
 = 180 
W
M
 = 1 × 180
2
/130
2
 = 1.538 → 1.6 (round up) 
W + W
M
 = 1 + 1.6 = 2.6 
Enter “2.6” for the Weight Parameter. 
Automatic speed setting by Weight 
140
120
100
80
60
40
20
0 1 1.5 2  2.5 3 (kg) 
Weight setting 
(%) 
*  The percentage in the graph 
is based on the speed at 
rated weight (1 kg) as 100%.
100
Automatic acceleration/deceleration setting by Weight 
140
120
100
80
60
40
20
0 1  1.5 2  2.5 3 (kg) 
Weight setting 
(%) 
*  The percentage in the graph is 
based on the acceleration 
/ deceleration at rated weight 
(3 kg) as 100%. 
110 
80 
110 
70 
90 
100 
70 
60 
G3-25*** 
G3-30*** 
G3-35*** 