Scara Robot Manipulator Manual
Setup & Operation    3. Environments and Installation 
3.7    User Wires and Pneumatic Tubes 
CAUTION
■ 
Only authorized or certified personnel should be allowed to perform wiring.  
Wiring by unauthorized or uncertified personnel may result in bodily injury and/or 
malfunction of the robot system. 
User electrical wires and pneumatic tubes are contained in the cable unit. 
Electrical Wires 
Rated Voltage 
Allowable 
Current 
Wires Nominal Sectional Area  Outer Diameter Note 
AC/DC30 V  1 A  15  0.211 mm
2
ø8.3±0.3 mm
Shielded
 Maker Standard 
Suitable Connector JAE
DA-15PF-N (Solder type) 
15 pin 
Clamp Hood  JAE
DA-C8-J10-F2-1R (Connector setscrew: #4-40 NC)
Pins with the same number, indicated on the connectors on both ends of the cables, are 
connected. 
Pneumatic Tubes 
Max. Usable Pneumatic Pressure Pneumatic Tubes  Outer Diameter × Inner Diameter 
2 
ø6 mm × ø4 mm 
0.59 MPa (6 kgf/cm
2 
: 86 psi)
1 
ø4 mm × ø2.5 mm 
Fittings for ø6 mm and ø4 mm (outer diameter) pneumatic tubes are supplied on both ends 
of the pneumatic tubes. 
Common Parts 
Fitting (white) for   
ø6 mm pneumatic tube 
Fitting (black) for   
ø6 mm pneumatic tube 
Brake release   
button switch 
15-pin D-sub connector 
Fitting (black) for 
ø4 mm pneumatic tube 
G3 Rev.1  33 