Scara Robot Manipulator Manual
Setup & Operation    2. Specifications 
G3 Rev.1  11 
2.2    Model Number and Model Differences 
G3-25 1 S □-R-UL 
Fire resistant 
□
: No fire resistant 
UL : UL compliance 
Type 
□
: Standard 
R : Right-Curved 
L : Left-Curved 
Environment 
S : Standard 
C : Cleanroom & ESD (Anti-Static) 
Joint #3 stroke 
: 150 mm 
1
: 120 mm (Cleanroom-model) 
Arm length 
25 : 250 mm 
30 : 300 mm 
35 : 350 mm 
Mounting type 
□
: Table Top Mounting 
M : Multiple Mounting 
Environment 
Cleanroom-model 
This model has additional features that reduce dust emitted by the Manipulator to enable 
use in clean room environments. 
For details on the specifications, refer to Setup & Operation: 2.4 Specifications. 