User`s manual

3-1
Section 3 Installation
3-1 Mounting Procedure
(1) Mounting procedure
1) Insert the @E.Terminal unit into the mounting panel (max. thick: 5 mm).
Panel cut-out deimensions
(Unit:mm)
Panel cut hole
Mounting panel
2) Insert four fixtures attached to the @E.Terminal unit into the mounting holes, and tighten them with
the tightening screws.
Tightening torque: 0.5 to 0.7 N m
75$
.1#&'4
75'441/%#4&
5:$75
+0
176
24VDC
FG

470
76'4/
6'4/
5612
10.
'44
741/
470
#./
$#6
0Q
%27
Fixture dimensions
(Unit: mm)
Fixtures
Mounting holes
Mounting panel
Fixtures
* When the @E.Terminal unit is attached to the mounting panel, the fixtures and frame grounds (FG) are connected.
To prevent static electricity, be sure to connect the mounting panel to the frame ground.
3) Mount the gasket so that it will be sandwiched securely between the @E.Terminal unit and the mounting panel.
Note) @E.terminal cannot be vertically mounted.
.