User`s guide
Chapter 4:Starting Up ScanShop
30 - ScanShop User’s Guide
into a single (multi-page TIFF or PDF) file. The exit code of sshop_cli
will be the number of pages scanned.
-start=n1
See above.
-stop=n2
See above.
-step=n3See above.
-ifile=filename
When the GUI version of ScanShop is launched, pre-loads the base
window canvas with image data from file filename.
-ofile=filename
Write resulting scan data to file filename. Default name is “scan.tmp”.
When using page auto-numbering with multiple scans, filename should
contain a “%d” (or similar printf-style format specification) to indicate
where the page number is to be inserted. If any
number option
parameters (
start, stop, or step) have been assigned, ScanShop will
append “%d” by default.
-fsbfilter=pathname
Sets the path/filter for Motif/OpenLook file selection boxes (not valid for
sshop_cli).
-pdpi=n
Specifies the dpi (dots per inch) of images read from files which do not
denote dpi explicitly. Affects printed size.
-debug=n
Diagnostic trace level set to n.
Examples
To scan an 8” by 11” document to file tmp.rs:
% sshop_cli -bits=1 -length=11i -width=8i -format=ras\
-ofile=tmp.ras -xres=200 -yres=200
Same as above, but using settings file “letter.ss”:
% sshop_cli -ifs=letter.ss
The file letter.ss contains:
format ras