Electrical
Note:
This product is also made for IT power systems with phase-to-phase
voltage 220 to 240 V. See the printer’s label for voltage information.
Ink Cartridges
Mechanical
Environmental
Safety Approvals
Specification 120 V Model 220240 V Model
Input voltage range 90 to 132 V 208 to 264 V
Rated frequency range 50 to 60 Hz
Input frequency range 49 to 61 Hz
Rated current 1.4 A 0.7 A
Power consumption Approx. 130.5 W (ISO/IEC 10561 Letter
Pattern); 29 W or less in standby mode
Print yield
Photographic Dye ink:
Approx. 28 pages/A0 (720 dpi, 40% duty);
approx. 6400 pages/A4 (360 dpi, 5% duty)
Archival ink:
Approx. 30 pages/A0 (720 dpi, 40% duty);
approx. 7,400 pages/A4 (360 dpi, 5% duty)
Print yield may vary, depending on how
often you run cleaning cycles and how
much you use the printer; yield of the
initial cartridge set is reduced because of ink
charging
Cartridge life 2 years from the production date
Photographic Dye ink:
2 years after opening package, at 77 °F
(25 °C)
Archival ink:
6 months after opening package, at 77 °F
(25 °C)
Dimensions Height: 6.6 inches (168 mm)
Depth: 13.54 inches (344 mm)
Width: 1.19 inches (30.3 mm)
Weight Approximately 1.9 lb (860 g)
Capacity 16.9 oz (500 ml)
Temperature Storage (uninstalled):
22 to 104 °F (
30 to 40 °C)
1 month at 104 °F (40 °C)
Storage (installed):
4 to 104 °F (
20 to 40 °C)
1 month at 104 °F (40 °C)
Transit:
22 to 140 °F (
30 to 60 °C)
1 month at 104 °F (40 °C)
120 hours at 140 °F (60 °C)
Freezing:
5 °F (
15 °C); ink thaws and is usable after
at least 3 hours at 77 °F (25 °C)
Paper feed
method
Friction
Paper path Roll paper with manual insertion; cut sheets
with either autoload or manual insertion
Dimensions Width: 73.4 inches (1865 mm)
Depth: 26.5 inches (673 mm)
Height: 48.2 inches (1225 mm)
Weight 291 lb (132 kg) with stand
Temperature Operation: 50 to 95 °F (10 to 35 °C)
Storage:
4 to 104 °F (
20 to 40 °C)
1 month at 104 °F (40 °C)
Transit:
4 to 140 °F (
20 to 60 °C),
stored in shipping container
120 hours at 140 °F (60 °C)
Humidity
(without
condensation)
Operation: 20 to 80% RH
Storage: 20 to 85% RH
Transit: 5 to 85% RH (stored in
shipping container)
Safety standards UL 1950, CSA C22.2 950
EMC FCC part 15 subpart B, class A
CSA C108.8 class A