Level 2 Options
l DSR - When DSR (Data Set Ready) is OFF, the signal
level is permanently set HIGH, allowing the printer to send
data to the computer. The factory setting is OFF (signal level
HIGH). For most communications purposes, this option should
be set to OFF. When DSR is ON, data is sent to the computer
only when DSR is HIGH.
Menu/submenu
Available options
ON or OFF
l CTS - When CTS (Clear To Send) is OFF, the signal level is
permanently set HIGH. The factory setting is OFF (signal level
is HIGH). This setting should be set to OFF for most
communications purposes. When CTS is ON, data is sent to
the computer only when CTS is HIGH.
Menu/submenu
Available options
ON or OFF