Service manual
4-50
CONFIDENTIAL
EMP-1825/EMP-1815/EMP-1810
SEIKO EPSON Revision:C
C A U T I O N
Follow the procedure below to install the PS Ballast Assy.
1). Route the Lamp Cable (igniter not-attached side) as shown below.
Figure 4-59.
2). Route the Lamp cable (igniter attached side) through the groove indicated
by the red box in the figure below. Make sure that the Lamp cable is not
routed under the PS Board.
Figure 4-60.
hooks
Lamp cable