Service manual
4-39
CONFIDENTIAL
EMP-1825/EMP-1815/EMP-1810
SEIKO EPSON Revision:C
C A U T I O N
(EMP-1815/1825 only) When reassembling the USB Board Assy., attach the
USB Shading Sheet drawing out the connector’s ribs from the hole as shown
in the figure.
Figure 4-47.
(EMP-1815/1825 only) When installing the Conduction Plate; Fan, follow the
standard below
• Align it at an angle of 25°±5° from the bottom of the board as shown in the
figure below.
Figure 4-48.
USB Shading Sheet
Conduction Plate; Fan