Service manual
4-32
CONFIDENTIAL
EMP-1825/EMP-1815/EMP-1810
SEIKO EPSON Revision:C
Removing EMI Suppressor/EMI Suppressor E (EMP-1825’s case)
16).Remove the seven EMI Suppressors from the back of the IM Board Assy.
17).Remove the two EMI Suppressor E in the same manner.
Figure 4-35.
Removing MA Shield Plate/Shield Plate Fasten (EMP-1810 only)
1).Remove the two screws (C.C.SCREW,3X6,F/ZN-3C) that secure the Shield Plate Fas-
ten, and remove the Shield Plate Fasten.
2).Remove the screw (C.B.P-TITE SCREW,2.5X10,F/ZN-3C) that secures the MA Shield
Plate, and remove the MA Shield Plate.
Figure 4-36.
C A U T I O N
In EMP-1825’s case,
seven EMI Suppressor and two EMI Suppressor E are
attached on the back of the IM Board Assy. Refer to Figure 4-37 (p. 33) for
attaching locations.
When replacing the IM Board Assy., refer to the instructions on the next page
and attach EMI Suppressor and EMI Suppressor E to the specified locations.
IM Board Assy.
EMI Suppressor E
EMI Suppressor
Shield Plate Fasten
MA Shield Plate
C.B.P-TITE SCREW,
2.5X10,F/ZN-3C