Service manual
4-28
CONFIDENTIAL
EMP-1825/EMP-1815/EMP-1810
SEIKO EPSON Revision:C
4.4.1.1. Removing the IF Board Assy.
1. Remove the IF Shade Sheet from the MA Board Assy.
2. Remove the eight screws (Screw, HSH 4-40) that secure the D Sub15pin terminals and the
two screws (C.B.P-TITE SCREW,3X8,F/ZB-3C) that secure the RCA terminals and S-
terminal.
3. Remove the screw (C.C.SCREW,3X6,F/ZN-3C) that secures the IF Board Assy.
4. Remove the two screws (C.C.SCREW,3X6,F/ZN-3C) that secure the IF-IM Plate, and
remove the IF-IM Plate together with the IF Board Assy. from the MA Board Assy.
Figure 4-31.
Screw, HSH 4-40
IF Board Assy.
MA Board Assy.
IF Shade Sheet
IF-IM Plate
C.B.P-TITE SCREW,
3X8,F/ZB-3C
Screw, HSH 4-40