Service manual
4-19
CONFIDENTIAL
EMP-1825/EMP-1815/EMP-1810
SEIKO EPSON Revision:C
C A U T I O N
When attaching the Lens Shutter Sheet to the Lens Shutter, follow the
standard below.
• Align the sheet to the red lines.
• Protrusion: 0mm (outside)/ within 1mm (inside)
Figure 4-17.
After replacing the Photo Interrupter, always perform operation check as
described below.
1). Turn the power on with the Lens Shutter open.
2). After confirming that the blue image (default) is displayed, close the Lens
Shutter as shown below. If the image turns black, there is no problem with
the parts or the connection.
Figure 4-18.
Lens Shutter Sheet
Lens Shutter
Lens Shutter