Service manual

4-17
CONFIDENTIAL
EMP-1825/EMP-1815/EMP-1810
SEIKO EPSON Revision:C
C A U T I O N
Secure the SW cable and the ferrite core of the Control Panel to the Upper
Case with heat-resistant tape according to the standard below.
Red lines: 4.5cm ± 5mm in between.
Blue lines: attach the ferrite core in the center between the lines.
Green lines: the same length as the Control Panel.
Figure 4-14.
Fold the SW Cable outward at 90 degrees between the Wireless LAN socket and
the rib shown in (1), then fold back the cable inward at 180 degrees aligning it
with its right edge as shown in (2).
Secure the fold with heat resistant tape as shown in (3).
Figure 4-15.
No caught cables, or floating case is allowed.
Connect the following connectors.
SW cable
(1) (2) (3)
LAN Socket
Rib
Tape
Connector No. Connected to
CN1201 Lamp Lid Detection SW
CN1203 Control Panel
CN1204 Photo Interrupter