Service manual
4-15
CONFIDENTIAL
EMP-1825/EMP-1815/EMP-1810
SEIKO EPSON Revision:C
4.3.4.1. Removing the Control Panel E/
Lamp Lid Detection Switch
1. Remove the Control Panel E from the Upper Case Unit AJ.
2. Remove the screw (C.C.B-TITE SCREW,2X12,F/ZN-3C) that secures the Lamp Lid
Detection Switch, and remove the Lamp Lid Detection Switch from the Upper Case Unit
AJ.
3. Remove the following parts from the Upper Case Unit AJ.
• Upper Case Sheet
• PJ Lens Cushion B
• Sensor Sheet
• LG Shading Sheet
• Ferrite Core
• LED Lens (* EMP-1825/1815 only)
• LED Cushion (* EMP-1825/1815 only)
Figure 4-12.
Control Panel E
Upper Case Sheet
PJ Lens Cushion B
Lamp Lid Detection Switch
Cushion LED*
LED Lens*
LG Shading Sheet
Ferrite Core