Service manual
3-12
CONFIDENTIAL
EMP-1825/EMP-1815/EMP-1810
SEIKO EPSON Revision:C
3.3.4 Connection Check
Flowchart 3-4 Connection Check (1)
C A U T I O N
Before starting the checking work, be sure to turn off the power and detach the
AC cable. (refer to 3.2.2 "Cable Connection and Projector’s Status" (p. 6))
MA board CN1300
Start
Control Panel
EX Fan
MA board CN1203 (Lock-type connector)
MA board CN1304
Photo Interrupter
MA board CN1204
MA board CN1300
MA board CN1205
MA board CN1302ޔCN1303
MA board CN1900/CN2000/CN2100 (Lock-type connector)
Light Valve R/G/B
Intake Fan A,B
L/V thermistor
RC board
TH board
To Next Page
Remove
Upper Case
For more information, refer to 4.3.4 "Removing the IF-IM Case/Upper Case Unit AJ" (p. 13) /
4.4.1 "Removing the Optical Engine and MAB (1) (MA Board Assy.)" (p. 20)