Service manual

3-8
CONFIDENTIAL
EMP-1825/EMP-1815/EMP-1810
SEIKO EPSON Revision:C
Connection (EMP-1825/1815 only)
Status
MA board Connected to
CN502 IM board The power can turn on and the projection starts nor-
mally. On the bottom left, the message that EasyMP is
starting continues to be displayed for a few minutes. But
the menu button works normally. Then, the message that
something happens to EasyMP and ask to press [?] for
help is displayed.
IM board Connected to
CN1303 MA board
CN801 USB board
The power can turn on and the projection starts nor-
mally. If the projector is connected to the network with
the wireless LAN unit, the projector cannot be recog-
nized. But if the wireless LAN unit is not used, this error
can be slipped over, so be careful.
CN1300 IS board The power can turn on and the projection starts nor-
mally. If the [QuickSetup] button is pressed, the Quick
Setup function does not work, instead, the message
"The measurement of Quick Setup cannot be done.
Please check the setting of the projector." is displayed.
The control from the rear does not function. The control
from the front is still effective.
• (Note: The setting of the RC receivers (active/inac-
tive) is available from the menu. So, check the setting
of the corresponding receiver before applying the
remedy.
IS board Connected to
CN10 IM board
Table 3-4. Mal-connection and the Projector’s Status