Lamp or Temp indicator flashes orange: Warning
ON Blink OFF Varies according to the projector status
Table 3-3. LED Indicator Status (Warning)
Indicator Status
Projector
Status
Problem and Remedy
High Temp Warn-
ing
(This is not an abnormality. However, if the temperature rises
too high again, projection stops automatically.)
• Check that the air filter and air exhaust vent are clear, and
that the projector is not positioned against a wall.
• If the air filter is clogged, clean or replace it.
(refer to 3.3.2 "Abnormality Check" (p. 10) / 4.3.2 "Removing
the Air Filter Assy." (p. 11))
Replace Lamp
Replace it with a new lamp.
If you continue to use the lamp after the replacement period has
passed, the possibility that the lamp may explode increases.
Replace it with a new lamp as soon as possible. (refer to 4.3.2
"Removing the Air Filter Assy." (p. 11))
OrangeRed
Orange