Service manual

3-5
CONFIDENTIAL
EMP-1825/EMP-1815/EMP-1810
SEIKO EPSON Revision:C
Lamp or Temp indicator flashes orange: Warning
ON Blink OFF Varies according to the projector status
Table 3-3. LED Indicator Status (Warning)
Indicator Status
Projector
Status
Problem and Remedy
High Temp Warn-
ing
(This is not an abnormality. However, if the temperature rises
too high again, projection stops automatically.)
Check that the air filter and air exhaust vent are clear, and
that the projector is not positioned against a wall.
If the air filter is clogged, clean or replace it.
(refer to 3.3.2 "Abnormality Check" (p. 10) / 4.3.2 "Removing
the Air Filter Assy." (p. 11))
Replace Lamp
Replace it with a new lamp.
If you continue to use the lamp after the replacement period has
passed, the possibility that the lamp may explode increases.
Replace it with a new lamp as soon as possible. (refer to 4.3.2
"Removing the Air Filter Assy." (p. 11))
OrangeRed
Orange