5-3
2. Type
A:
, then press
Enter
(
C:\>A: Enter
).
3. Make sure the
A:\>
prompt appears on the computer screen.
4. Type
CD RS353AS
; then press
Enter
(
A:\> CD RS353AS Enter
).
5. Make sure the
A:\RS353AS>
prompt appears on the computer screen.
6. Type
CD AS6
; then press
Enter
(
A:\RS353AS>CD AS6 Enter
)
7. Make sure
A:\RS353AS\AS6>
appears on the screen.
8. Type
RS353ASE
then press
Enter
(
A:\RS353AS\AS6>RS353ASE Enter
)
Image Adjustment Program Menu
After the program starts, the following display appears on the computer screen.
LCP Image Adjustment RS-353 Ver 2.10 SEIKO EPSON
0 Initialization
1 Flicker Adjustment
2 Ghost Adjustment
3 Sub Contrast Adjustment
4 Data Transfer
5
6
7
8
9 END
Select the number [1-9]
0. Initialization
Type
0
. The message “SET LCP COMMUNICATION MODE” appears on the computer
screen after you select this menu. Then, the program feeds data automatically into the
registers for gamma registration. The projector displays the red, green, and blue
grayscale patterns to allow you to adjust flicker, ghosts, and contrast.
1. Flicker Adjustment
1. Type
1
from the main menu to adjust the flicker.
2. Make sure the projector displays the 16-level red-scale pattern at the top of the
screen. (Dark patterns appear on the left side; brighter patterns on the right side.)
Figure 5-3.