Service manual

EPSON ELP-3500 Service Manual
3-5
3.2.2 Removing the Upper Case Unit and Handle
Handle Holder Cover
Figure 3-4.
Screws
Figure 3-5.
1. Pull the handle up. Insert the spring hook into either hole in the handle holder cover
and, while pressing the spring hook toward the hole on the opposite side, pull it up to
remove the handle. Bend the center of the handle holder cover up, forming an arch.
2. Remove 2 screws beneath the handle holder cover.
Screws: +M3x12 F/Zn P-Tight: P/N 1021823
Mounting torque: 6.0 kg cm = 5.2 lb inch
3. Remove 4 case unit fixing screws on both sides.
Screws: +M4x8 F/ZB Bind: P/N 1033026
Mounting torque: 6.0 kg cm = 5.2 lb inch
Caution:
The handle holder cover has claws on both ends. They may be damaged if you insert the
spring into a hook's hole and simply pulling it up.
(Continued on the next page)