Reference Guide

166 Product Information
Electrical
Environmental
Character sets: 13 international character sets and one legal character
set: USA, France, Germany, UK, Denmark I,
Sweden, Italy, Spain I, Japan, Norway,
Denmark II, Spain II, Latin America, Legal
Rated voltage range: 100 to 240 V
Input voltage range: 90 to 264 V
Rated frequency range: 50 to 60 Hz
Input frequency range: 49.5 to 60.5 Hz
Rated current: 4.8 A (maximum 14.5 A)
Power consumption: Approx. 185 W (ISO/IEC 10561 letter
pattern)
Approx. 9.5 W in sleep mode
Printer status Temperature Humidity
(without
condensation)
Operating (plain paper) 5 to 35°C (41 to 95°F) 10 to 80% RH
Operating (recycled paper,
envelope, label, or roll
paper)
15 to 25°C (59 to 77°F) 30 to 60% RH
Storage –30 to 60°C (–22 to 140°F) 0 to 85% RH