System information
__________________________________________________
Blastware Compliance Module
Blastware Operator Manual 4–69
a. Unit Operating System
This is the release number and version number of the operating system presently in the monitor.
b. Disk Operating System
This refers to the unit operating system stored in the Blastware program.
c. Compliance Report Type
This drop-down menu displays the current type of report loaded into the monitor. It also lists the
available compliance reports in Blastware that you can choose to load into the monitor.
To choose a compliance report, click on the Compliance Report Type drop-down menu and
select a report.
d. Printer Driver Type (Minimate Plus, Minimate Blaster and Micromate Only)
Three printer models are supported for the Minimate Plus and Minimate Blaster: the Kodak
Diconix 180 SI, Hewlett Packard DeskJet 320, and the Canon BJ-30 in Epson LQ mode. Choose
the driver corresponding to your printer.
If your printer type does not correspond to either of these printers, choose the Canon BJ-30 in
Epson LQ mode driver for printers capable of emulating the Epson LQ mode. Set the printer
scaling to two–thirds of a page. For printers using Hewlett Packard’s PCL printer language,
choose the HP DeskJet 320 driver.
The Citizen CMP-30 Printer is compatible with the Micromate monitor.
To choose a driver, click on the Printer Driver Type drop–down menu and select a driver.
e. Language
Different languages can be loaded into the monitor and used. This drop-down list identifies the
Language Library files available for use.
To choose a language, click on the arrow and select. The Language Library must be loaded into
the monitor. To load the Language Library, choose either the Reload OS and Library
Components command to reload the operating system along with the language library, or the
Reload Library Components Only command to load only the language library.
NOTE: New language files may be created using the Language Editor available in the Blastware
Advanced software (optional – Series III only).
f. Modem (Minimate Pro Only)
Instantel supports a variety of modems. Modems are controlled by script files.
To choose a Modem, click on the arrow and select. The Modem must be loaded into the monitor.
To load the Modem script file, choose either the Reload OS and Library Components command
to reload the operating system along with the Modem script file, or the Reload Library
Components Only command to load only the Modem script file.
g. Vibration Dose Value (VDV) Frequency Weights (Series IV Only)
This option is only available if you have purchased the Blastware Advanced Module. The VDV
monitoring option is used to measure and determine whole-body vibration based on a Frequency
Weighting file that is downloaded from Blastware. Your geographic location and the type of
vibration that you are monitoring will determine which Frequency Weighting file that you
choose to use during the monitoring session – the frequency range of the data collected is from 1
to 80 Hz. Two frequency weighting files may be downloaded to the monitor, which can then be
assigned to daytime or nighttime monitoring sessions.
To choose a Frequency Weights file, click on the arrow and select. The Frequency Weights file
must be loaded into the monitor. To load the Frequency Weights file, choose either the Reload
OS and Library Components command to reload the operating system along with the
Frequency Weights, or the Reload Library Components Only command to load only the
Frequency Weights file.