System information

__________________________________________________
Blastware Compliance Module
Blastware Operator Manual 4–37
(8) Backlight on Time
This command sets the length of time the backlight remains on by setting an adjustable timer from
0 to 255 seconds. To disable the backlight and not have it turn on, set the timer delay to 0. This
conserves battery power.
To set the Backlight on Time, click on the Backlight on Time box and enter a new time.
(9) Power Saving Timeout
The Power Saving Timeout is a timer that automatically turns the monitor off when it has
remained in the ready to monitor mode while detecting no key presses for a specified period of
time. This conserves battery power. The monitor will also turn off while connected to a computer
but automatically turns on again when the computer communicates with the monitor.
To set the Power Saving Timeout, click on the Power Saving Timeout box and enter a new time.
(10) Monitoring LCD Cycle
The Monitoring LCD Cycle is a timer that automatically starts a power saving mode. While in this
mode, the monitor minimizes power consumption while continuing its monitoring operations. The
monitor turns the display off for the time period set in this command, turns on the display
momentarily, then cycles the display off again. To turn this feature off, set the time to zero. To
reactivate the monitor and see the display, press the On/Off key.
To set the Monitoring LCD Cycle, click on the Monitoring LCD Cycle box and enter a new time.
(11) Set Unit Time with Setup
To synchronize the Unit clock with the personal computer clock, place a checkmark in the box
prior to selecting Send to Unit. Disable Set Unit Time with Setup by clicking on the checkbox
to clear the checkmark.
(12) Command Buttons
To choose one of the following command buttons, click the mouse pointer on the button.
i Cancel
Exit the dialog box and return to the Blastware Main Menu.
ii Send To Unit
Transfer your settings to the monitor.
h. Printer Setup (Blastmate III Only)
To display the Printer Setup dialog box, open the Unit, Setup, Compliance Setup menu and
select the Printer Setup tab.
The Printer Setup dialog box configures the Event Summary Report printed by the Blastmate III
printer. Settings include when the report is printed, how many copies will be printed, and the
reports contents. After you have entered your settings in each dialog box, choose Send To Unit to
transfer your settings to the monitor.