System information
__________________________________________________
Blastware Compliance Module
Blastware Operator Manual 5–11
5.4.5 Sensor Check
This command runs Sensor Check, which checks the Blastmate II or the Minimate Geophone and
microphone sensors. To display the dialog box, open the Unit Menu and choose Sensor Check.
a. Test Results
This area displays the results of the Sensor Check. In addition to indicating the Pass/Fail status,
the display offers basic information on the sensor. For the microphone, the frequency (FR) and
ampere rating (AMP) are given. For the Geophone, the frequency (FR) and overswing ratio
(OSR) are shown for each of the transverse, vertical and longitudinal sensors.
(1) Mic Test
This displays the results of testing on the microphone.
(2) Tran Test
This displays the results of testing on the Geophones transverse sensor.
(3) Vert Test
This displays the results of testing on the Geophones vertical sensor.
(4) Long Test
This displays the results of testing on the Geophones longitudinal sensor.
(5) Test button
This runs Sensor Check and tests the sensors connected to the monitor. Click on the Test button.
b. Sensor Check Mode
You can choose to have the unit run Sensor Check regularly, either before or after Events are
recorded. The results are stored with the Event file, and are displayed in the Quick View window
in the Event Manager