Blastware Compliance Module
Blastware Operator Manual 5–9
f. Charge Weight (Blastmate II Only)
Enter the charge weight of the blast in pounds or kilograms.
g. Scaled Distance (Blastmate II Only)
The Scaled Distance is calculated automatically, and appears within this dialog box and on Event
Summary Reports.
h. Command Buttons
To choose one of the following command buttons, click the mouse pointer on the button.
i OK
Accept the changes and do not exit the dialog box.
ii Cancel
Cancel the changes and return to the previous window.
iii Apply
Apply the changes and exit the dialog box.
iv Help
Select Help to launch the menu to access help on the Series II dialogs.
5.4.3 Timer Mode Setup
The timer function sets a Blastmate II or a Minimate to automatically turn on and start monitoring
operations at a preset time in the future. The timer can be set for a one time monitoring session or
to record at the same time every day. Using the timer extends the monitors battery life by turning
on and monitoring only the time periods when Events occur and not the time periods between
Events.
To display the Timer Mode Setup dialog box, select Unit, Setup, and then click on Compliance
Setup.
Note: When using a monitor in the Timer Mode, the monitor stops recording even if Event
activity is present and exceeds the trigger levels. The monitor records the current Event