System information

__________________________________________________
Blastware Compliance Module
Blastware Operator Manual 5–7
enough so the monitor does not trigger on unwanted Events such as nearby vehicle traffic. At the
same time, you have to set the trigger level low enough so that an Events activity exceeds the
trigger level and starts the monitor recording.
To set a trigger level, click on the Trigger Level box. Enter the new level.
ii Alarm Level (Blastmate II Only)
The alarm level controls the triggering of an optional remote alarm (711A1401).
The remote alarm sounds two alarms: warning and alarm. The warning alarm sounds when Event
activity exceeds the set Geophone trigger level. The alarm level can be set to a different level that
is higher than the trigger level of the Geophone. This allows for the triggering of a second alarm at
the higher level.
For example, in pile driving operations the remote alarm triggers a warning when activity exceeds
the trigger level for the Geophone, notifying the operator that the pile driving activity has
exceeded that set level. The second alarm triggers when activity exceeds the alarm level, set to a
higher level, notifying the operator to reevaluate the piling operation.
To set an alarm level, click on the Alarm Level box. Enter the new level.
(10) Microphone
The following options setup the microphone channel for recording.
Note: The microphone must be enabled as a trigger source before these settings can be changed.
i Weighting (Blastmate II Only)
Choose the microphone type connected to the monitor. Choose either Linear, A Weight, or C
Weight.
To choose a microphone type, click on the Weighting drop–down menu. Choose a type.
ii Trigger Level
The trigger level sets a threshold that must be exceeded by an Events activity before the monitor
begins recording. Use your judgment when setting a trigger level. You must set the level high
enough so the monitor does not trigger on unwanted Events such as nearby vehicle traffic. At the
same time, you have to set the trigger level low enough so that an Events activity exceeds the
trigger level and starts the monitor recording.
To set a trigger level, click on the Trigger Level text box. Enter the new level.
iii Alarm Level (Blastmate II Only)
For a description of the optional remote alarm, see to the Geophone channel in the previous
section.
To set an alarm level, click on the Alarm Level box. Enter the new level.
iv Range (Blastmate II Only)
Set the range for Strip-Chart record mode only. The Range controls the plotter (printer) output on
the monitor. The range also controls the sensitivity of the monitor.
To choose a range, click on the Range drop–down menu. Choose a range.
b. Command Buttons
To choose one of the following command buttons, click the mouse pointer on the button.
i OK
Accept the changes and do not exit the dialog box.
ii Cancel
Cancel the changes and return to the previous window.