User`s manual

20
20
5.6. Software Status Setting
When system POWER ON, there is no need to turn off to modify Command
Type, Baud Rate, Parity, Demo Mode and International Character. To re-set
DIP Switch to various Command Type under the following list of Command
to modify the setting. The setup value will be stored in the EEPROM.
When DIP Switch is OFF. Next time the system POWER ON previous setup
value will be the default value and no need to modify.
5.6.1. Baud rate
STX 05 B n ETX /Set baud rate and keep it with EEPROM/
ASCII Format STX 05 B n ETX
Dec. Format [02][05][66] n [03]
Hex. Format [02h][05h][42h] n [03h] 30h n 34h
Description Change the display communication baud rate.
The baud rate setting can be selected from 4800 to 38400.
N Baud rate
30h 4800
31h 9600
32h 19200
33h 38400
5.6.2 International character set
STX 05 S n ETX /Change international character set/
ASCII Format STX 05 S N ETX
Dec. Format [02][05][83] n [03]
Hex. Format [02h][05h][53h] n [03h] 30h n 3fh
Description Change the display international character font .A
total of 16 different character fonts to select form.
The setting function will be saved to EEPROM.
N International font n International font
30h U.S.A. 38h JAPAN
31h 39h NORWAY
32h GERMANY 3Ah DENMARK II
33h U.K. 3Bh SLAVONIC
34h DENMARK I 3Ch RUSSIA
35h SWEDEN 3Dh U.S.A.
36h ITALY 3Eh Not used
37h SPAIN 3Fh User define pattern